Federal grant · project grant (b)
Leadless Pacemaker Betavoltaic Power Source - Project Summary Lithium-based Batteries Have Reached a Technological Limit of ~0.6 CC for Use in Leadless Cardiac Pacemaker (LCP) Applications and a Useful Life of Only 7-10 YEARS1. the 0.6 CC Volume Comprises Over 60% of the LCP’S Total Volume and Is a Technological Miniaturization Limit to LCPS. City Labs Is Developing a Small Betavoltaic Power Source With Sufficient Current Density to Power a Pulse Generator Circuit. the Battery’s Volume Can Be as Small as 0.1 CC, While Providing a Consistent ≥3.8 ΜW for 20 Years. This Size Reduction Would Allow for an LCP to Be Implanted in the Atria, Permitting Multi-chamber Leadless Pacing for Patients Previously Relegated to Conventional Pacemakers. Furthermore, a Decrease in Size Grants Both the Manufacturer of Delivery Catheters and the Clinicians Operating Them a Higher Degree of Flexibility, Both in Developing the Device Design Process and Implantation Protocol, Even Permitting Multiple LCPS in a Single Chamber. a Longer-lived Pacemaker Also Expands the Potential Use of LCPS to Younger Demographics. LCPS’ Retrieval Is Difficult, So They Are Often Used in Patients Who Are Not Projected to Outlive the DEVICE2,3. We Will Be Designing and Manufacturing a Polyimide-based Package That Will Be Biocompatible and Safe. It Will Fit in a Leadless Pacemaker’s Titanium Housing, Providing Double Encapsulation. the Project Goal Is to Make the Most Reliable Polyimide Device Configuration and Manufacturing Approach for Transition to Market Approval With the Pacemaker Manufacturing Partner. We Propose a Research and Development Optimization of Industrial Production Methods Necessary to Ensure Consistent and Controlled Scale-up Manufacturing According to Recognized Quality Standards and Fda Requirements. City Labs Has Developed and Utilized Helium Generation and Leak Models for the Predictive Design of Packaging and Components Indicative of Measured Values. Model and Measured Data Will Undergo Rigorous Tuning and Analysis Under This CRP to Ensure Adequate Predictability and Tolerance for Diffusion Rates in a Polyimide Package. Furthermore, All Packages Will Be Tested to Ensure They Meet the Designed Leak Rate. the Final Optimization of the Prototype Entails the Sealing of End Caps, Feedthroughs, Wall Thickness, and Leak Rates Associated With Components and Sealing Processes. We Will Quantify the Component and Sealing Process Leak Rates With a Helium Leak Detector. This Will Enable Us to Produce a Package, With Controlled Hermeticity and Minimized Volume, From Components Fabricated In-house, Like Additively Manufactured End Caps and Specialized Electrical Contacts. to Fabricate and Seal Such Polyimide Components, We Will Acquire and Customize an Advanced 3-D Printer Capable of Manipulating High Performance Thermoplastics. the CRP Effort Will Support Development Needed to Harmonize the Modeling, Prototyping, and Manufacturing Processes. This Project Aims to Develop the Manufacturing Capability and Commercialization Maturity Our Pacemaker Manufacturing Partners Require.
Committed
$472,571
Paid out
$251.2K
53%
Committed, not yet paid
$221.4K
47%
Loading…
Everything here is this single award's whole record — signed, amended, paid — not a fiscal-year slice. The by-year charts elsewhere split an award across the years it was committed; this page keeps it whole.
Committed is what the government has legally promised on this award so far. Contracts can also carry a ceiling — the maximum if every option is exercised. Unspent ceiling is headroom, not money owed.
The cash actually disbursed against this award. The gap from committed is the disbursement pipeline: promised, not yet cashed.
Each transaction is a signing event — an action that created or changed the award, dated the day it was signed — not a payment. Negative amounts are real: money de-committed at closeout or renegotiation.
One bar, the award’s whole arithmetic: paid out, then committed, not yet paid, then unspent ceiling.